体位及机械通气对危重病人中心静脉压的影响
来源: 2010-08-24 09:10:39
【Abstract】 Objective To investigate the effect of posture and mechanical ventilation(MV) on central venous pressure(CVP) in critically ill patients. Methods 23 critically ill patients were enrolled in this study with MV and CVP measurement. CVP, heart rate(HR), mean arterial pressure(MAP),oxygen saturation of pulse(SpO2),and Riker’s sedation-agitation score(SAS) were obtained simultaneously with a backrest elevation of 30° or with a supine flat position at different MV conditions. Results There was no difference between CVP of the two positions at the same MV condition(P>0.05). CVP increased gradually by the increment of positive end expiratory pressure(PEEP) with both positions(P<0.05). SpO2 decreased and SAS increased when the position was adjusted from 30° to supine and when the ventilator was detached with both positions. There were no difference in HR and MAP between different positions and between different MV conditions. Conclusions CVP wasn’t influenced by the posture. CVP increased gradually with the increment of PEEP. Changing posture and detaching ventilator led to the deterioration of oxygenation and agitation. Maintaining of posture and MV when measuring CVP could improve the security and comfortableness of patients,and reduce the work of nursing.
【Key Words】 Central venous pressure; Posture; Mechanical ventilation; Positive end expiratory pressure
中心静脉压(CVP)广泛用于评估血容量及心脏前负荷,很早以前人们就发现体位对健康人CVP没有明显影响[1],但在危重病人中尚无一致结果[2~4];机械通气(MV)可使中心静脉压增加,其中以呼气末正压(PEEP)作用最为明显[5];但同时改变体位与机械通气水平对中心静脉压的影响尚了解不多。目前ICU中CVP监测需调节病人至平卧位并脱开呼吸机,测量过程繁琐并给患者带来一定的风险与不适。本研究旨在评估不同体位及机械通气条件对CVP的影响,探寻“真实”条件下与常规条件下所测得的CVP间的联系,为简化CVP测量程序,增加病人的安全性与舒适性提供理论依据。
1对象与方法
1.1 对象
选择2005年12月~2006年3月因患各种疾病需要机械通气及中心静脉压测量的患者23例,男17例,女6例;年龄30~87岁,平均(57.8±14.9)岁。[样本含量是否计算?是否为住院病人?]
1.2 方法
本研究为前瞻性自身对照研究,患者体位设定为30°卧位与平卧位。患者均接受呼吸支持(Puritan-Bennett 840型呼吸机,美国Tyco集团);SIMV+PSV模式,指令频率8次/分,潮气量8ml/kg,压力支持水平根据呼吸机监测到的呼出潮气量调整,使呼出潮气量约等于8ml/kg;流量触发,触发灵敏度2L/min;吸入氧浓度根据病情调整,控制在35%~80%;PEEP设为0、3、6、9、12、15cm H2O 6个水平,测定时由低到高逐渐递增。经右锁骨下静脉置入中心静脉导管(深圳益心达公司)后,床旁拍摄胸部正位X片,确认导管尖端位于上腔静脉与右心房交汇处。
在不同研究条件下,使用IntellivueMP60型心电监护仪(荷兰Phillips公司)测量患者的CVP、心率(HR)、平均动脉压(MAP)、指脉搏血氧饱和度(SpO2);患者的Riker镇静-躁动评分(SAS)[6]。中心静脉压参考点固定在右侧腋中线与第四肋间交点处,使用水平尺调整压力传感器保证参考点与传感器位于同一水平。首先测量脱机时30°卧位和平卧位时的各参数,此后每隔1小时测量某一PEEP值机械通气时两体位下的各参数,PEEP值由0至15cmH2O递增,每次增加3cmH2O。
1.3统计学处理
统计数据以x ±SD表示,总体比较采用三因素方差分析,脱机时两体位比较采用配对t检验,P<0.05表示差异有统计学意义。
2 结果
2.1体位对CVP等的影响
30°卧位与平卧位比较,两体位间CVP、HR及MAP总体无明显变化。30°卧位时SpO2明显高于平卧位(P<0.000),SAS评分较平卧位低(P<0.000),说明患者半卧位时较平卧位氧合更佳,躁动程度更轻,剔除神经系统疾病致昏迷患者后,两组SASa评分比较结果相似。结果见表1。
表1 两体位各参数总体间比较(